At least 89%Listed solid content
45-60 minListed dissolving time
At least 180 CListed temperature resistance
FM201 high salty resistance polymer bag
White FM201 drilling polymer powder

FM201 is listed as a white powder or granule for drilling-fluid applications.

Core Facts

Specifications That Shape Handling Discussions

Appearance White powder or granule
Solid content At least 89%
Particle size 20-40 mesh
Bulk density 0.80-1.02 g/cm3
0.1% solution viscosity Medium to high; high in salty conditions
Temperature resistance At least 180 C
Dissolving time 45-60 minutes
Listed packaging 25 kg and 1000 kg bags

Keep the system in view

These listed characteristics frame the conversation, but they do not replace a review of water quality, temperature, circulating conditions and the complete mud system for a specific well.

A Focused Starting Point

Map the Salt Load Before You Discuss the Additive

A concise brief helps align the product conversation with the conditions that can influence slurry behavior and field preparation.

01 / WATER AND FORMATION

Describe the salinity exposure

Identify whether seawater, formation brine, recycled water, salt layers or ion contamination is part of the operating picture.

02 / PROGRAM BOUNDARY

Set the thermal and circulation context

Share the working temperature range, the required fluid-control focus and any conditions that affect mud handling through the interval.

03 / MIXING AND REVIEW

Plan the field conversation

Use the listed 45-60 minute dissolving window as a planning reference, then confirm the mixing procedure and performance checks for the actual system.

Adjacent Product Roles

Explore Related Drilling Additives

These separate products address different functions. Open the relevant product page when the project calls for a high-viscosity polymer, shale inhibition or a coating agent.

SHN-FM101 high viscosity polymer bag

SHN-FM101

A separate high-viscosity drilling polymer product for flow adjustment, friction reduction and shale-stability discussions.

View FM101
SHN-FM301 shale inhibition polymer

SHN-FM301

A separate shale-inhibition polymer positioned for reactive formations and wellbore-stability considerations.

View FM301
Offshore drilling platform shown on the SHN-CA101 product page

SHN-CA101

A separate low-molecular-weight coating agent for deepwater and cryogenic drilling-fluid programs.

View CA101

Related Reading

Questions to Bring Into Program Planning

Use these articles to frame technical discussions around high-salinity fluid behavior, field preparation and specification review.

Foundation Drilling Polymer Product Lines

Review how high-salinity and ion-polluted water conditions can shape polymer product-line conversations in foundation drilling.

Read the article

Specialized Drilling Slurry Polymer Technology

Explore the connection between saline, chloride-rich muds, fluid-loss control and rheological stability in drilling programs.

Read the article

Fluid-Loss Control Specifications

Consider how solid content, particle size, dissolving time and temperature resistance can influence field preparation discussions.

Read the article

FM201 FAQ

Key Questions for a High-Salinity Program

Where does FM201 fit in a high-salinity drilling program?

FM201 is intended for drilling fluid programs where saline or ion-polluted make-up water can affect viscosity and fluid-loss control. Offshore, salt-dome, deep-well and geothermal conditions are relevant planning contexts.

Which FM201 specifications should be checked before selection?

Key listed specifications include white powder or granule appearance, solid content of at least 89%, 20-40 mesh particle size, bulk density of 0.80-1.02 g/cm3, and medium-to-high viscosity in a 0.1% solution.

How long does FM201 take to dissolve?

FM201 has a listed dissolving time of 45-60 minutes. Confirm the proposed mixing procedure and the actual water conditions with SHN Chem for the project.

What temperature resistance is listed for FM201?

FM201 is listed with temperature resistance of at least 180 C. The operating program should still be reviewed against the well conditions and the complete mud system.

How is FM201 packaged and stored?

The page lists 25 kg and 1000 kg bags and recommends storage in a cool, dry place. Confirm packaging needs and delivery details when requesting a quotation.

What information should be included in an FM201 inquiry?

SHN Chem requests the product name, specification or grade, quantity, packaging, destination and application details so the team can discuss technical matching and quotation needs.

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
Name
Email *
Message
Leave a message
Name
Email *
Message